Créer un trunk Afin d’enregistrer un trunk Alphalink sur PBXware, plusieurs paramètres sont à configurer.  Assurez vous que l’adresse IP publique du PBXware est autorisée dans la liste blanche du trunk SIP. Rendez-vous dans la section Accueil > Trunks […]">
FR | EN
Wiki Bicom Systems EnglishWiki Bicom Systems English
  • Home
  • Documentation
    • PBXware
      • Installation
      • Getting started
      • Editions
        • PBXware Multi-Tenant
        • PBXware Business
        • PBXware Contact Center
        • PBXware Service Provider
      • Advanced services
      • Supported phones
      • Autoprovisioning
    • Communicator
      • Communicator Desktop
      • Communicator GO
      • Communicator Web
    • SERVERware
      • Standalone
      • Mirror
      • Cluster
    • sipPROT
    • Tutorials
  • Videos
    • Communicator Desktop
  • Operators
  • Downloads
  • FAQ
Support
leafleaf
Most popular:
  • PBXware
  • Communicator
  • SIP
  1. Home
  2. TUTORIAL: Register a SIP Trunk
  3. Alphalink
Updated on October 22, 2025
TUTORIAL: Register a SIP Trunk
  • Folder icon closedFolder open iconAlphalink
  • Folder icon closedFolder open iconBouygues
  • Folder icon closedFolder open iconCoMeeTT
  • Folder icon closedFolder open iconCloud Telecom
  • Folder icon closedFolder open iconDstny
  • Folder icon closedFolder open iconFlexnetwork
  • Folder icon closedFolder open iconFree PRO
  • Folder icon closedFolder open iconKeyyo
  • Folder icon closedFolder open iconLasotel
  • Folder icon closedFolder open iconMaxiconnect
  • Folder icon closedFolder open iconNexphone
  • Folder icon closedFolder open iconOVH
  • Folder icon closedFolder open iconOxiwi
  • Folder icon closedFolder open iconPeoplefone
  • Folder icon closedFolder open iconPhenix Partner
  • Folder icon closedFolder open iconRubix Telecom
  • Folder icon closedFolder open iconSewan
  • Folder icon closedFolder open iconStelogy
  • Folder icon closedFolder open iconTechcrea
  • Folder icon closedFolder open iconTelcoz
  • Folder icon closedFolder open iconUnyc
  • Folder icon closedFolder open iconVA Telecom
  • Folder icon closedFolder open iconVoxwide

Alphalink

Estimated reading: 2 minutes
ADD A SIP TRUNK

To create a SIP trunk, please see Register a SIP trunk > Create a trunk

In order to register an Alphalink trunk on PBXware, several parameters must be configured. 

Make sure that the PBXware public IP address is allowed in the SIP trunk whitelist.

Go to the section Home > Trunks located on the left side panel of PBXware (position yourself in the Master-Tenant in the case of a Multi-Tenant edition) and click the button Add a Trunk.

Choose Generic SIP as provider and click on Next step.

Fill in the following fields:

  • Name or number: Enter a name for your trunk
  • User type:peer
  • Peer host: sip.openvno.net, sip2.openvno.net or sip3.openvno.net (depends on your trunk)
  • Peer username: trunk username (0990000…)
  • Peer secret: trunk password

Show the advanced options and configure the following options:

  • Qualification (ms): 16000
  • Pass-thru mode: Yes
  • Sign up/Register: With username
  • Inbound IP addresses :
95.140.14.192/27 217.15.80.160/28 217.15.80.248/29 217.15.88.160/28 217.15.95.0/25 130.93.0.0/25 95.140.14.224/27 217.15.88.192/28 217.15.88.248/29 185.120.179.160/27 130.93.0.224/27 217.15.80.163 217.15.95.97 217.15.95.98

Finally, fill in the following additional configuration so that the trunk can automatically re-register in case of an outage (expand the additional configuration field at the bottom of the page by clicking the button Advanced) :

[registration] expiration=120 auth_rejection_permanent=no max_retries=1000 retry_interval=60 fatal_retry_interval=60 forbidden_retry_interval=120

In order to check whether the SIP trunk is properly registered, go to Admin settings > Asterisk CLI, then type the following command:

pjsip show registrations 